Model |
MPLFLN40X |
MPLAPON60X |
MPLAPON100XO2 |
Magnification |
40 |
60 |
100 |
Numerical Aperture |
0.75(N.A) |
0.9(N.A) |
1.45(N.A) |
Working distance(MM) |
0.63 |
0.4 |
0.1 |
Field(mm) |
26.5 |
26.5 |
26.5 |
Thickness of cover glass (mm) |
0 |
0 |
0 |
Infusion |
Air / dry |
Air / dry |
oil |
Spring |
yes |
Correction ring |
Not applicable |
Remarks (Correction Collar) |
|
|
Not applicable |
Aperture diaphragm |
Not applicable |
Apochromatic aberration(APO) |
Correction level of color difference |
Semi achromatic(FL) |
Apochromatic aberration(APO) |
45 |
Confocal distance(mm) |
45 |
45 |
-19.1 |
Back focal plane(BFP)position(mm) |
-19.1 |
-19.1 |
W20.32×0.706 (RMS) |
Thread type |
W20.32×0.706 (RMS) |
W20.32×0.706 (RMS) |
Insufficient |
Bright field (reflection) |
excellent |
Bright field (transmission) |
excellent |
Not applicable |
Dark field (reflection) |
Not applicable |
Dark field (transmission) |
good |
Not applicable |
DIC(Differential interference difference)(reflex) |
Not applicable |
good |
DIC(Differential interference difference)(transmission) |
Insufficient |
Not applicable |
differ |
Not applicable |
Phase contrast |
Phase contrast |
good |
Polarized light |
Insufficient |
good |
fluorescence(B,Ginspire) |
Insufficient |
good |
UVfluorescence (365nm) |
Insufficient |
Notapplicable |
multiphoton |
Not applicable |
TIRF |
Not applicable |
IR |
Not applicable |
WLI |
Not applicable |
Auto focus (IX3-ZDC2) |
Auto focus |
N5702700 |
Product Number |
N2699400 |
N2756500 |
1-UXB270 |
UPC Code |
1-U2M527 |
1-U2M931 |
|
Precautions for using objective lens
1. Do not disassemble the parts of the microscope at will.
2. The optical part of the microscope should not be touched by hand.
3. Rotate the rotator above the objective lens when transforming the objective lens. Hand-held objective lens conversion is not allowed.
4. If you do not use the microscope for a long time, please turn the brightness of the electric light source of the microscope to the lowest level (maintain the life of the lamp).
5. When the specimen plate needs to be replaced, turn the object lens away from the loading platform and lower or place the specimen plate.
6. After the use of the microscope, it must be restored. The specific steps are as follows: first turn the converter to make the object lens leave the light hole, then take the subscript film, lower the loading platform, lower the condenser, close the aperture, return the slide mobile, adjust the brightness of the electric light source of the microscope to the darkest, then turn off the power, cover the silk cloth and outer cover, and finally put the microscope in the center of the table.